Sanada, Yukihisa; Oshikiri, Keisuke*; Kanno, Marina*; Abe, Tomohisa
Nuclear Instruments and Methods in Physics Research A, 1062, p.169208_1 - 169208_7, 2024/05
As part of the decommissioning work at the Fukushima Daiichi Nuclear Power Plant (FDNPP), the release of stored treated water began in 2023. In this study, we developed a practical tritium monitor to continuously monitor the concentration of tritiated water, as confirmed by batch sampling measurements at the FDNPP. The monitor is arranged with a flow cell detector comprising inexpensive plastic scintillator pellets and incorporating simultaneous measurements by three detectors, a veto detector, and lead shielding to reduce the influence of environmental -rays. The system reached a detection limit of 911 Bq L-1 with a measurement time of 30 min, which is lower than the discharge standard for tritiated water of 1,500 Bq L-1. The system can also qualitatively distinguish the presence of disturbances due to interfering radionuclides other than tritium or background radiation using the -ray spectrum.
Katengeza, E. W.*; Sanada, Yukihisa; Ochi, Kotaro; Iimoto, Takeshi*
Cogent Engineering (Internet), 11(1), p.2340203_1 - 2340203_9, 2024/04
The uncertainty of radioactivity measurements can be influenced by the vertical distribution of the target radionuclide in the sediments. This study used 2015-2019 field measurement data from 47 ponds to evaluate the depth dependence of calibration factors of plastic scintillation fiber (PSF) and its influence on measurement uncertainty. By changing the depth of focus from 10 cm to 15-20 cm when calculating the conversion factor, the normalized mean square error of the radiocesium concentration estimated by the PSF with respect to the radiocesium concentration in core sediments sampled at the same location was found to be smaller.
Shibata, Motoki*; Nakanishi, Yohei*; Abe, Jun*; Arima, Hiroshi*; Iwase, Hiroki*; Shibayama, Mitsuhiro*; Motokawa, Ryuhei; Kumada, Takayuki; Takata, Shinichi; Yamamoto, Katsuhiro*; et al.
Polymer Journal, 55(11), p.1165 - 1170, 2023/11
Times Cited Count:1 Percentile:44.82(Polymer Science)Koizumi, Mitsuo; Mochimaru, Takanori*; Hironaka, Kota; Takahashi, Tone; Yamanishi, Hirokuni*; Wakabayashi, Genichiro*
Nuclear Instruments and Methods in Physics Research A, 1042, p.167424_1 - 167424_6, 2022/11
Times Cited Count:2 Percentile:50.96(Instruments & Instrumentation)no abstracts in English
Takai, Shizuka; Namekawa, Masakazu*; Shimada, Taro; Takeda, Seiji
IEEE Transactions on Nuclear Science, 69(7), p.1789 - 1798, 2022/07
Times Cited Count:0 Percentile:0.01(Engineering, Electrical & Electronic)To reduce a large amount of contaminated concrete rubble stored in the Fukushima Daiichi Nuclear Power Station site, recycling low-radioactivity rubble within the site is a possible remedy. To promote recycling while ensuring safety, not only the average radioactivity but also the radioactivity distribution of concrete rubble should be efficiently evaluated because the details of rubble contamination caused by the accident remain unclear and likely include hotspots. However, evaluating inhomogeneous contamination of thick and/or dense materials is difficult using previous measurement systems, such as clearance monitors. This study experimentally confirmed the potential applicability of image reconstruction algorithms for radioactivity distribution evaluation in concrete rubble filled in a chamber. Radiation was measured using plastic scintillation fiber around the chamber (50 50 40 cm). Localized hotspots were simulated using standard sources of Cs, which is one of the main nuclides of contaminated rubble. The radioactivity distribution was calculated for 100 or 50 voxels (voxel size: (10 cm) or 10 10 20 cm) constituting the chamber. For 100 voxels, inner hotspots were undetected, whereas, for 50 voxels, both inner and surface hotspots were reconstructible. The distribution evaluated using the maximum likelihood expectation maximization algorithm was the most accurate; the average radioactivity was estimated within 70% accuracy in all seven cases.
Terasaka, Yuta; Watanabe, Kenichi*; Uritani, Akira*
Nuclear Instruments and Methods in Physics Research A, 1034, p.166793_1 - 166793_6, 2022/07
Times Cited Count:3 Percentile:66.21(Instruments & Instrumentation)Koizumi, Mitsuo; Takahashi, Tone; Hironaka, Kota; Mochimaru, Takanori*; Yamanishi, Hirokuni*; Wakabayashi, Genichiro*
Annual Report of Cooperative Researches at Kindai University Reactor, 2020, p.76 - 80, 2021/12
no abstracts in English
Sanada, Yukihisa
Hokeikyo Nyusu, (68), p.2 - 6, 2021/10
Due to the impact of the Fukushima Daiichi Nuclear Power Station accident (hereinafter referred to as the power station accident) of Tokyo Electric Power Company Holdings, Inc., the surrounding environment was contaminated with radioactive substances such as radioactive cesium. After the nuclear power plant accident, plastic scintillation fiber is one of the applied wire and surface radiation measurement techniques. This paper summarizes the development process from a series of development to the introduction of the actual machine.
Yamamoto, Takahiro; Ito, Chikara; Maeda, Shigetaka; Ito, Hideaki; Sekine, Takashi
JAEA-Technology 2017-036, 41 Pages, 2018/02
In the experimental fast reactor Joyo, the damaged upper core structure (UCS) was retrieved into the cask in May 2014 The dose rate on UCS surface was quite high due to the activation for over 30 years operation. In order to attain the optimum safety design, manufacture and operation of equipment for UCS replacement, the method to evaluate UCS surface dose rate was developed on the basis of C/E obtained by the in-vessel dose rate measurement in Joyo. In order to verify the evaluation method, the axial gamma-ray distribution measurement on the surface of the cask, which contained UCS, was conducted using a plastic scintillating optical fiber (PSF) detector. This paper describes the comparison results between calculation and measurement as follows. (1) The measured axial gamma-ray distribution on the cask surface had a peak on proper location with considering the cask shielding structure and agree well with the calculated distribution. (2) The C/E of axial gamma-ray distribution on the cask surface was ranged from 1.1 to 1.7. It was confirmed that the calculation for UCS replacement equipment design had a margin conservatively. Then, the results showed that the developed evaluation method for UCS replacement equipment design was sufficiently reliable.
Sanada, Yukihisa; Yamada, Tsutomu*; Sato, Yoshiharu; Nishizawa, Yukiyasu; Ishibashi, Satoshi*; Watanabe, Masahisa; Torii, Tatsuo
JAEA-Research 2016-011, 52 Pages, 2016/09
In the Tokyo Electric Power Co.,Inc. the Fukushima Dai-ichi Nuclear Power Station, management of the contaminated water becomes the social problem, and the situation that severe correspondence is necessary continues to prevent an outflow to the ocean. Plastic scintillation fiber (PSF) can apply as technique to direct measure the concentration of radioactive material in the water at a tank and drainage. In this paper, the results of fundamental test was summarized to apply for monitoring of leakage to the tank and monitoring of drainage in the Fukushima Dai-ichi Nuclear Power Station.
Nagasawa, Naotsugu; Taguchi, Mitsumasa
Isotope News, (736), p.47 - 50, 2015/08
no abstracts in English
Saito, Toru; Okubo, Toshikazu*; Izumi, Keisuke*; Okawa, Yoshinao*; Kobayashi, Norihiro*; Yamazaki, Toru; Kawano, Katsumi; Isono, Takaaki
Teion Kogaku, 50(8), p.400 - 408, 2015/08
Aramid fiber-reinforced plastic (AFRP) has been developed as a structural material that has the advantages of light weight and high strength. In this study, tensile tests were carried out to measure the tensile properties of AFRP rod on the market for reinforcement of concrete at room temperature, 77 K and 4.2 K. Especially at cryogenic temperatures, it is difficult to perform a tensile test of the bar because the specimen slips through the jig grip. To prevent the rod from slipping, tensile tests were carried out with some filling conditions. The applicable and appropriate tensile test conditions were established by modifying the jig grip, treating the surface of the rod and using cryogenic epoxy infill to grip the rod. They were more than 1100 MPa. Additionally, the AFRP rod included a temperature dependence in which the Young's modulus increased as the test temperature decreased. It was confirmed that the Young's modulus increased because aramid fiber was more dominant than epoxy.
Sanada, Yukihisa; Urabe, Yoshimi; Orita, Tadashi; Takamura, Yoshihide; Torii, Tatsuo
Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 5 Pages, 2015/05
There are approximately 3,700 irrigation ponds in the Fukushima prefecture. Contamination by radiocesium at the bottom of these ponds has been a concern since the accident at the TEPCO's Fukushima Daiichi Nuclear Power Station (FDNPS). Among them, there are some reservoirs which contain radioactive materials in the bottom sediment. Three years have passed since the accident of the Fukushima Daiichi Nuclear Power Station. In relation to the restoration of agriculture in the disaster-stricken area, there are concerns over the migration of radioactive cesium in the environment. We developed 20 meter-length a plastic scintillation fiber (PSF) for measurement in water. We have conducted tests at dozens of irrigation ponds in Fukushima pref. using PSF to confirm the performance of the devices and to standardize measurement techniques and analytical procedures.
Sanada, Yukihisa; Torii, Tatsuo
Nihon Genshiryoku Gakkai-Shi ATOMO, 57(2), p.94 - 98, 2015/02
In Fukushima, quick and direct technique to measure a wide area of bottom of water is needed. We developed the plastic scintillation fiber (PSF) since accident at 1F. Therefore, the PSF was applied to measurement of irrigation pond. Here, the measuring method and the monitoring result are reported.
Yagi, Toshiaki
Dai-14-Kai Hoshasen Riyo Gijutsu Semina; Hirogaru Hoshasen No Sangyo Riyo Koen Tekisuto, p.67 - 72, 2004/10
no abstracts in English
Suhartini, M.; Mitomo, Hiroshi*; Nagasawa, Naotsugu; Yoshii, Fumio; Kume, Tamikazu
Journal of Applied Polymer Science, 88(9), p.2238 - 2246, 2003/00
Times Cited Count:46 Percentile:79.75(Polymer Science)no abstracts in English
Suhartini, M.; Mitomo, Hiroshi*; Yoshii, Fumio; Nagasawa, Naotsugu; Kume, Tamikazu
Journal of Polymers and the Environment, 9(4), p.163 - 171, 2001/10
Times Cited Count:25 Percentile:66.12(Engineering, Environmental)no abstracts in English
Furutaka, Kazuyoshi
JNC TN8400 2000-028, 70 Pages, 2000/10
This report describes the study done by the author as a postdoctoral research associate at Japan Nuclear Cycle Development Institute. This report is divided into two parts: improvements in accuracy in determination of thermal neutron capture cross sections, and improvements in accuracy of photo-nuclear absorption cross section measurements using the HHS. (1)In the measurements of thermal neutron capture cross sections using an activation method, accuracies of the final results attained are limited by (1) accuracy of -ray peak detection efficiencies, and (2) accuracies of -ray emission probabilities. In this study; to determine thermal neutron capture cross sections more accurately, the following researches have been done using a newly developed three-dimensional coincidence measurement system: (1)accurate determination of -ray standard sources using a - coincidence method, for precise calibration of -ray peak detection efficiency, and (2) development of a - coincidence measurement system using a plastic scintillation detector as a -ray detector, for the determination of -ray emission probabilities of short-lived nuclides, and measurement of -ray emission probabilities of Tc nuclide using the coincidence system. (2)To transform radioactive nuclides with small thermal neutron capture cross sections, use of photonuclear absorption reaction has been suggested. In order to transform these nuclides efficiently using the reaction, one has to know detailed behavior of the photo-absorption cross sections. In this study, a Monte-Carlo simulation code has been used to create a standard set of -ray response functions of the high-resolution high-energy spectrometer (HHS), to enable reliable analyses of the data obtained by the spectrometer.
Hatakeyama, Mutsuo; Ito, Hirokuni; Yanagihara, Satoshi
JAERI-Tech 2000-056, 38 Pages, 2000/09
no abstracts in English
Nakane, Yoshihiro; Sakamoto, Yukio
Proceedings of 10th International Congress of the International Radiation Protection Association (IRPA-10) (CD-ROM), 5 Pages, 2000/05
no abstracts in English